Product range
Grandezza
Size
|
RPM |
P1 |
P2-P1 [mbar] |
P2/P1 |
T1 [°C] |
T2 [°C] |
T2-T1 [°C] |
| MAX |
MIN (1) |
MAX |
MIN |
MAX |
MAX |
MAX |
MIN |
MAX |
MAX |
|
15
|
5000 |
1200 |
P0+50 |
P0-500 |
900 |
2 |
35 |
-25 |
130 |
110 |
| 25 |
700 |
90 |
|
35
|
5000 |
1000 |
P0+100 |
P0-500 |
1000 |
2 |
50 |
-25 |
150 |
130 |
| 45 |
1000 |
110 |
| 46 |
700 |
90 |
|
55
|
4800 |
900 |
P0+100 |
P0-500 |
1000 |
2 |
50 |
-25 |
150 |
130 |
| 65 |
1000 |
110 |
| 66 |
700 |
90 |
|
75
|
3800 |
700 |
P0+100 |
P0-500 |
1000 |
2 |
50 |
-25 |
150
(2) |
130 |
| 85 |
1000 |
110 |
| 86 |
700 |
90 |
|
95
|
3000 |
550 |
P0+100 |
P0-500 |
1000 |
2 |
50 |
-25 |
150
(2) |
130 |
| 105 |
1000 |
110 |
| 106 |
700 |
90 |
|
115
|
2400 |
450 |
P0+100 |
P0-500 |
24.0 |
2 |
50 |
-25 |
150
(2) |
130 |
| 125 |
32.0 |
110 |
| 126 |
1.10 |
90 |
|
135
|
1800 |
350 |
P0+100 |
P0-500 |
1000 |
2 |
50 |
-25 |
150
(2) |
130 |
| 145 |
1000 |
110 |
| 155 |
700 |
90 |
|
165
|
1500 |
300 |
P0+100 |
P0-500 |
1000 |
2 |
50 |
-25 |
150
(2) |
130 |
| 175 |
1000 |
110 |
| 205 |
1200 |
250 |
P0+100 |
P0-500 |
1000 |
2 |
50 |
-25 |
150
(2) |
110 |
|
225
|
700 |
90 |
|
|
P0
|
=
|
Atmospheric pressure
|
|
P1
|
=
|
Blower absolute inlet pressure
|
|
P2
|
=
|
Blower absolute outlet pressure
|
|
T1
|
=
|
Blower inlet temperature
|
|
T2
|
=
|
Blower outlet temperature
|
| |
|
|
| Notes: |
|
| (1) |
|
Resonance phenomena in the plant are possible
when speed of rotation is close to the minimum
|
| (2) |
|
160°C for blowers /R-F
|
| |
|
|
Homepage
Products Positive
displacement rotary blowers
Product range
|