Products
logoRobuschi_CMYK.jpg

Rotary lobe blowers from Robuschi are engineered for high-efficiency air movement in pressure and vacuum applications. This technical data asset consolidates performance specifications for the full RBS series—from compact units like RBS 15 to high-capacity models like RBS 205—covering flow rates, pressure differentials, motor sizing, acoustic profiles, and material standards.

Use this page to compare blower configurations and select the right unit for your application.

Full Spec Sheet

Access the complete technical document with performance tables, material specifications, and installation dimensions.
Rotary Lobe Blowers: Technical Data Spec Sheet

Performance Overview

All data is based on atmospheric air at:

  • Pressure: 1,013 mbar
  • Temperature: 20°C
  • Humidity: 50%
  • Density: 1.2 kg/m³

For non-standard gases or operating conditions, contact Robuschi.

 

Key Parameters

  • Q1 (m³/min): Flow rate
  • DT (°C): Temperature rise
  • Nsof (kW): Absorbed power
  • Nmot (kW): Recommended motor power
  • Lp(A) sc: Sound pressure level at 1m without enclosure
  • Lp(A) cc: Sound pressure level at 1m with enclosure

Model Highlights

 

ModelMax Flow (m³/min)Max Nmot (kW)Max Lp(A) sc (dB)
RBS 154.67.587
RBS 255.87.590
RBS 358.91592
RBS 4512.73095
RBS 5517.345101
RBS 6524.255107
RBS 7528.575103
RBS 8542.0110106
RBS 9546.390102
RBS 10560.3118105
RBS 11572.0142102
RBS 12592.5180105
RBS 126130.5110+106
RBS 135111.513296
RBS 145162.0355105
RBS 155201.5500100
RBS 165179.4251106
RBS 175242.3475113
RBS 205263.3522109
RBS 225398.8546109

 

Material Standards

All components meet international standards:

  • Rotors & Shafts: EN 1563 GJS 400-15, DIN 1696 0.7040, ASTM A536 GR 60-40-18
  • Casing & Covers: EN 1561 G250, DIN 1691 0.6020, ASTM A48 GR 30
  • Gears: EN 10084 18NiCrMo5, DIN 17212 1.6523, ASTM A534 Cl 4720

Custom material configurations are available on request.

 

Acoustic Performance

Sound pressure levels are measured per ISO 3746:

  • Without enclosure (Lp(A) sc): 74–113 dB(A)
  • With enclosure (Lp(A) cc): <70–85 dB(A)

Noise enclosures reduce sound levels by 10–25 dB(A), depending on model and operating conditions.

 

Installation & Dimensions

  • Max discharge temperature: 150°C (160°C for R-F configurations)
  • Minimum RPM: Model-specific; resonance risks at low speeds
  • Flange drilling: UNI PN10 or ANSI 125 FF
  • Pressure gauge connection: G3/8”
  • Flow direction: Vertical, top to bottom

Refer to pages 29–34 of the spec sheet for full layout drawings and weights.

FAQs

Nsof is the actual absorbed power. Nmot is the recommended motor power to safely handle that load.